Search found 2084 matches

by jeanmarc
Sat Nov 21, 2020 4:09 pm
Forum: Power-one inverters
Topic: 123solar questions
Replies: 5
Views: 67

Re: 123solar questions

Getting wrong data either from the com app or you inverter is not normal ;) You can skip those wrong data by changing scripts/protocols/aurora.php .. if ($FRQ > 0 || $INVT > 100 || $BOOT > 100) { // Avoid null values at early startup $RET = 'OK'; } else { $RET = 'NOK'; } then restart 123s, that won'...
by jeanmarc
Sat Nov 21, 2020 7:35 am
Forum: Power-one inverters
Topic: 123solar questions
Replies: 5
Views: 67

Re: 123solar questions

123s just show what your com app return. What protocol are you using ?
For example, using aurora i sometimes get a grid frequency of 0Hz
by jeanmarc
Fri Nov 20, 2020 7:24 pm
Forum: Others inverters
Topic: Smart meter P1 AC values + Power One inverter
Replies: 3
Views: 71

Re: Smart meter P1 AC values + Power One inverter

yeah that will be lost after update.
You can see all variables details in scripts/protocols/_protocols.txt
by jeanmarc
Fri Nov 20, 2020 5:01 pm
Forum: Others inverters
Topic: Smart meter P1 AC values + Power One inverter
Replies: 3
Views: 71

Re: Smart meter P1 AC values + Power One inverter

Hi, That would need to adapt the scripts/protocols/aurora.php file. Somewhere near line 75 $P1values = exec("something to get your smart's meter grid values"); $decodedP1 = do somethings; .. $G1V = "grid phase 1 data from $decodedP1"; .. $G2V = "grid phase 2 data"; .. $...
by jeanmarc
Fri Nov 20, 2020 4:48 pm
Forum: meterN
Topic: Peaks in power inputs when production sample is missing
Replies: 15
Views: 371

Re: Peaks in power inputs when production sample is missing

123s write 123s_LIVEMEMORY and mN use pool123s to read it. You can see value in MEMORY via admin/help.php page. Both mN and 123s LIVEMEMORY are tracking live things (latests samples), _MEMORY is used for various needs i don't have the time to explain the "nuts and bolts". I believe my code...
by jeanmarc
Thu Nov 19, 2020 9:07 pm
Forum: meterN
Topic: Peaks in power inputs when production sample is missing
Replies: 15
Views: 371

Re: Peaks in power inputs when production sample is missing

No, mN just read data from your com. apps, it dosen't make any calculation. You don't use latest pool123s.php, i guess a value is empty or not numeric (maybe thought it's text). You could help your debug by outputting values in a file or with echo .. $log = 'mylog.txt'; $stamp = date('d/m/Y H:i:s');...
by jeanmarc
Tue Nov 17, 2020 6:20 pm
Forum: meterN
Topic: Peaks in power inputs when production sample is missing
Replies: 15
Views: 371

Re: Peaks in power inputs when production sample is missing

polvere79 wrote: Ok, so metern uses pool123s.php (which is a comapp, right?) to get data from 123s JSON file, but then its metern.php writing data in metern csv files?
Yup and eflow read mN's CSV to make calculation. I don't know why i write that crap around 5 years ago :lol:
by jeanmarc
Mon Nov 16, 2020 6:45 pm
Forum: meterN
Topic: Peaks in power inputs when production sample is missing
Replies: 15
Views: 371

Re: Peaks in power inputs when production sample is missing

123s get datas directly from your inverter and write 123s's CSV and JSON files in memory. mN get datas using various com apps. To read 123s there is pool123s.php that read 123s JSON file, simple as that :) It also mean that if you reboot your PC on night the 123s JSON dosen't exist. eflow is bad as ...
by jeanmarc
Mon Nov 16, 2020 5:39 pm
Forum: meterN
Topic: Peaks in power inputs when production sample is missing
Replies: 15
Views: 371

Re: Peaks in power inputs when production sample is missing

I don't understand your question, 123solar.php writre csv and 123s_LIVEMEMORY.json. You better not modify it, your com app should do the job to check values are correct like if they are empty or not.