Search found 1757 matches

by jeanmarc
Tue Jun 18, 2019 6:16 pm
Forum: Power-one inverters
Topic: Continuous warning after upgrade to 1.8.x
Replies: 12
Views: 74

Re: Continuous warning after upgrade to 1.8.x

:idea: Could you also try this script php test.php (correct /dev and stop 123s) <?php $filter = "W011,W001,E011"; exec("aurora -a 2 -A /dev/solar", $ALARM); /// no edit print_r($ALARM); $ALARM = implode(PHP_EOL, $ALARM); $found = false; if (trim($ALARM) && !strpos($ALARM, 'W0') && !strpos($ALARM, 'N...
by jeanmarc
Tue Jun 18, 2019 5:55 pm
Forum: Power-one inverters
Topic: Continuous warning after upgrade to 1.8.x
Replies: 12
Views: 74

Re: Continuous warning after upgrade to 1.8.x

thanks, what more /srv/http/123solar/config/config_invt1.php | grep FILTER return ?
by jeanmarc
Tue Jun 18, 2019 2:02 pm
Forum: Power-one inverters
Topic: Continuous warning after upgrade to 1.8.x
Replies: 12
Views: 74

Re: Continuous warning after upgrade to 1.8.x

There is no worries with those returns, they are just data not reals alarms.
I've reviewed the code, i don't see where that come from.
Please update to 1.8.3.2, also i really need to see files in msgqueue/ to see why it happen.
by jeanmarc
Mon Jun 17, 2019 7:15 pm
Forum: Power-one inverters
Topic: Continuous warning after upgrade to 1.8.x
Replies: 12
Views: 74

Re: Continuous warning after upgrade to 1.8.x

So you get this on rpinotify | pushover | mail ?
You definitely should have files in msgqueue before it happens.
Do you run latest version ?
by jeanmarc
Mon Jun 17, 2019 4:55 pm
Forum: Pulse meters
Topic: Match a pulse meter with a real meter
Replies: 1
Views: 441

Re: Match a pulse meter with a real meter

I guess it's resolved with "Redefine index(es)" option ;)
by jeanmarc
Mon Jun 17, 2019 4:53 pm
Forum: Pulse meters
Topic: Gas pulses metering
Replies: 0
Views: 10

Gas pulses metering

Hello, I've been struggling since years with my gas meter (an Actaris G4 RF1), actually counting with a IR sensor was not the best option. Mostly when the temperature rise the resistor vary and lead to false pulses. Since few days i use a sensitive hall sensor that detect the magnet and perfectly fi...
by jeanmarc
Mon Jun 17, 2019 8:04 am
Forum: Power-one inverters
Topic: Continuous warning after upgrade to 1.8.x
Replies: 12
Views: 74

Re: Continuous warning after upgrade to 1.8.x

That's ok to me..
What files are in data/invt1/msgqueue/ ?
by jeanmarc
Sun Jun 16, 2019 9:12 pm
Forum: Power-one inverters
Topic: Continuous warning after upgrade to 1.8.x
Replies: 12
Views: 74

Re: Continuous warning after upgrade to 1.8.x

did you have debug enabled, any notification filters ?
When it happens, what files are in data/invt1/msgqueue/ ?
by jeanmarc
Sun Jun 16, 2019 4:10 pm
Forum: Power-one inverters
Topic: Continuous warning after upgrade to 1.8.x
Replies: 12
Views: 74

Re: Continuous warning after upgrade to 1.8.x

Hi Leo,
What odd messages :shifty: Do you use aurora protocol or someting like socat ?
Stop 123s and what return aurora -a 2 -A /dev/ttyUSB0 (adapt it) ?
by jeanmarc
Sun Jun 16, 2019 4:04 pm
Forum: meterN
Topic: meterN 1.0
Replies: 21
Views: 840

Re: meterN 1.0

Hello,

Here a small mN 1.1.1 update that correct few things :

- Bug gauge on Firefox
- Bug when decomminssioning
- Avoid warning when testing com. apps if mN if already stopped

Bye