Search found 5 matches

by aszczupal
Sun Sep 23, 2018 3:52 pm
Forum: Others inverters
Topic: ZeverSolar TLC5000
Replies: 1
Views: 2288

ZeverSolar TLC5000

Hi i have fresh PV installation based on Zeversolar TLC5000 inverter (5,6 kWp) I want to monitor it by 123solar .. ( I have running "MeterN" on my Eastron SDM630 meter) Have You any idea how Can Log data from it ? ( I have full dokumentation about registers etc...) and us in 123solar ? ( and in Mete...
by aszczupal
Wed Dec 07, 2016 4:53 pm
Forum: meterN
Topic: MeterN and three phases system
Replies: 9
Views: 2610

Re: MeterN and three phases system

Hi It is no clean for me.. Why You do not get all parameters from SDM630 ? my result.. ------------------------------------ [root@domek SDM630]# ./sdm630_1 1_1_1F(234.0*V) 1_1_2F(234.2*V) 1_1_3F(234.7*V) 1_1(234.30*V) 1_2_1F(1.03*A) 1_2_2F(0.99*A) 1_2_3F(2.17*A) 1_2(4.74*A) 1_3(50.0*Hz) 1_1F(213.26*...
by aszczupal
Thu Mar 17, 2016 11:19 am
Forum: M-Bus S-Bus Modbus meters
Topic: EASTRON SDM630DC
Replies: 11
Views: 55127

Re: EASTRON SDM630DC

Hi , I did it myself . I put some modifications to original program in C ( for example rounded some value....) Here are results... :D # ./sdm630_1 1_1_1F(236.4*V) 1_1_2F(238.6*V) 1_1_3F(239.4*V) 1_1(238.17*V) 1_2_1F(0.48*A) 1_2_2F(0.74*A) 1_2_3F(0.76*A) 1_2(2.54*A) 1_3(50.0*Hz) 1_1F(83.23*W) 1_2F(15...
by aszczupal
Fri Mar 04, 2016 11:38 am
Forum: M-Bus S-Bus Modbus meters
Topic: EASTRON SDM630DC
Replies: 11
Views: 55127

Re: EASTRON SDM630DC

Hi . No , because SDM120 take only information from 1 phase.. , I need information from 3 phase total.. SDM630 use different register for that. I'am not able to modify SDM120C program... It would be best if Pongo (gianfrdp) will modify his great program ( I wrote to him..) . but... no answer yet:) b...
by aszczupal
Thu Mar 03, 2016 10:08 pm
Forum: M-Bus S-Bus Modbus meters
Topic: EASTRON SDM630DC
Replies: 11
Views: 55127

Re: EASTRON SDM630DC

Hello everybody. This is my first post..
I just start MeterN witch SDM630C.
Do You have a "pooler" script like a "pooler485" from SDM120C to prepare proper "meter1.txt file ?

Regards
Adam